Air check O2 Ex Oxygen Deficiency Monitor

Air check O2 Ex Oxygen Deficiency Monitor

  • Suitable for Class 1 Div 1 Group B,C,D
  • No maintenance Zirconium cell
  • No calibration required
  • No drift to environmental or temperature changes
  • 10 + year Sensor life
  • Local display
  • 4-20 mA analog output.
  • Built-in flow sample pump
  • User adjustable alarm relays
  • Suitable for remote sampling to 100 feet
Price   $2950.00
  • Features

    The Air check O2 Deficiency Monitor is a compact sample draw gas monitoring system that’s ideal for the continuous monitoring of inert gas storage areas, confined spaces, and other locations where low oxygen levels may pose a hazard to personnel. Unlike electrochemical sensor cells the Air check O2 zirconium cell provides stable oxygen readings even in areas where temperature and humidity levels are changing. The PureAire Air check O2 Deficiency Monitor is suitable for either indoor or outdoor use.

    The heart of the monitoring system is a long lasting zirconium sensor, which responds to low oxygen conditions within seconds and provides accurate measurements over a wide temperature and humidity range. The zirconium O2 sensor cell will operate continuously for 10 or more years and requires an absolute minimum of maintenance. There are no zero or span calibration pots to adjust and when compared to disposable type sensors, our long life zirconium O2 sensor can save up to $475 annually and will pay for itself in just over 3 years!

    Ideal for continuously monitoring oxygen levels in confined spaces or areas where inert gases are used, the Air check O2 Deficiency Monitor does not drift or loose sensitivity when the weather or temperature changes. The electronics are housed in an Explosion proof weather resistance housing.

  • Specifications
    Sampling Method Sample Draw
    Gases Detected Oxygen (O2)
    Range 0 - 25 % O2
    Accuracy ± 1 % of Full Scale
    Operating Temperature -40 to +55 ºC
    Display 3/4” backlit digital display
    Sensor Type Long life zirconium oxide sensor cell
    Sensor Life 10+ years under normal conditions
    Signal Outputs 4-20 mA analog output
    Power Requirements 24 VDC
    700 mA
    Width 6.625 in
    168 mm
    Height 5.50 in
    140 mm
    Depth 5.25 in
    134 mm
    Weight 12 lb
    5.5 kg
    Enclosure Explosion proof Class 1, Div 1, Group B C and D
    Required Calibration None
    No Zero or Span Pots Supplied
  • Advantages

    Connects to DCS and PLC Controls

    The Air check O2 Deficiency Monitor is 24VDC powered and transmits continuous oxygen concentration levels to any distributive control system, programmable logic controller or PureAire’s proprietary single and multichannel controllers. The Air check O2 Deficiency Monitor can be operated remote up to 1,000 meters, 0.6 miles from centralized distributive control systems.

    PureAire’s Oxygen Sensor Cell

    The Air check O2 Deficiency Monitor uses an exclusive Current Limiting Zirconium Oxide Oxygen sensor that never requires a reference gas. Unlike concentration type zirconium cells that must have a reference gas, PureAire’s O2 monitor can operate in 100% nitrogen environments. Capable of detecting 0% up to 100% oxygen levels, the current limiting O2 sensor operates at a lower temperature than competitive concentration type cells. The average life of PureAire’s O2 sensor is over 8 years in most environments.
    The Air check O2 Deficiency Monitor never needs calibration. The earth is a wonderful source of calibrated oxygen and under ambient levels; PureAire’s O2 monitor is continuously being challenged to 20.9%. There are no zero or span adjustments to make; the only optional response test required is to subject the O2 system to nitrogen periodically.

    O2 Monitor System Features

    The Air check O2 Deficiency Monitor is available in many different configurations. PureAire uses a sophisticated built-in CPU that is flexible to provide users with a low cost basic display only monitor or a full featured monitor with dual level, user selectable alarm relays. When supplied with built-in alarm relays, the Air check program continuously monitors electronics, sensor cell and sample flow status. Fault information is sent to the mA output, alarm relay and front panel LED.